Table 111: Radiation weighting factors

Type and energy range

Radiation weighting factor, wR

Photons, all energies

1

Electrons and muons, all energies

1

Neutrons, energy

<10 keV

5

10 keV to 100 keV

10

100 keV to 2 MeV

20

2 MeV to 20 MeV

10

>20 MeV

5

Protons, other than recoil protons, energy >2 MeV

5

Alpha particles, fission fragments, heavy nuclei

20

 

11.2.2.3          Value of the tissue weighting factor, wT

a.              The values of the tissue weighting factor shall be as specified in Table 11‑2.

NOTE 1      The tissue weighting factor takes into account the variability in sensitivity of different organs and tissue subject to the same equivalent dose.

NOTE 2      The values in Table 11‑2 are from ICRP Publication 60 Table A-3 [11] and are defined and maintained by the ICRP. The users are encouraged to consult the ICRP for the more recent updates.